PRODUCT FEATURES:
Brand: APC
Power Capacity (VA): 3000VA
Model Number: SRT3000XLI
Output power capacity: 2.7 KWatts / 3.0 kVA
Max Configurable Power (Watts): 2.7 KWatts / 3.0 kVA
Nominal Output Voltage: 230V
Output Voltage Note: Configurable for 220 : 230 or 240 nominal output voltage
Output Voltage Distortion: Less than 2%
Output Frequency (sync to mains): 50/60Hz +/- 3 Hz
Topology: Double Conversion Online
Waveform Type: Sine wave
Output Connections: (8) IEC 320 C13 (Battery Backup)/(2) IEC 320 C19 (Battery Backup)/(2) IEC Jumpers (Battery Backup)
Nominal Input Voltage: 230V
Input Frequency: 40 – 70 Hz (auto sensing)
Input Connections: British BS1363A, IEC-320 C20, Schuko CEE 7/EU1-16P
Cord Length: 2.44meters
Input voltage range for main operations: 160 – 275V
Input voltage adjustable range for mains operation: 100 – 275 (half load)V
Number of Power Cords: 3
Other Input Voltages: 220, 240
Typical recharge time: 3hour(s)
Replacement Battery: APCRBC152
RBC Quantity: 1
Surge Energy Rating: 340Joules
Maximum Height: 43.2 cm
Maximum Width: 8.5 cm
Maximum Depth: 63.5 cm
Product Weight: 31.3 kg
Color: Black
Units Per Pallet: 12.0
Operating Environment: 0 – 40 °C
Operating Relative Humidity: 0 – 95%
Operating Elevation: 0-3000meters
Storage Temperature: -15 – 45 °C
Storage Relative Humidity: 0 – 95 %
Storage Elevation: 0-15000meters
Online Thermal Dissipation: 703.0BTU/hr
Protection Class: IP 20
Details: Provides early-warning fault analysis on batteries enabling timely preventive maintenance. Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection. Text and mimic diagrams that display modes of operation, system parameters and alarms. Protects the initial investment in the UPS when migrating from tower to rack-mount environment. Install maintenance releases of firmware remotely using FTP. Protects the initial investment in the UPS when migrating from tower to rack-mount environment. Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS. Minimizes installation costs by enabling the use of smaller generators and cabling. Ensures clean, uninterrupted power to protected equipment when generator power is used. Provides temporary battery power when the utility power is out. Provides remote power management of the UPS over the network. Customize UPS capabilities with management cards. Quickly understand unit and power status with visual indicators.